To be eligible for the BICSI OSP-002 Certification Exam, applicants must have a minimum of two years of experience in the ICT industry, specifically in outside plant infrastructure design, installation, and maintenance. In addition, applicants must have completed the BICSI OSP-001 course, which covers the basic principles and practices of outside plant design. Applicants can also meet the eligibility requirements through a combination of education and experience.

 

NEW QUESTION # 95
Reference cables must match the \_\_\_\_\_\_\_\_ of the cables being tested.

  • A. Fiber size and type
  • B. Fiber size and connector type
  • C. Fiber size and loss specification
  • D. Connector type

Answer: B


NEW QUESTION # 96
Singlemode fiber has a __________ light-carrying core than multimode fiber.

  • A. Smaller
  • B. Larger
  • C. Same size

Answer: A


NEW QUESTION # 97
Supports for UTP cables should be __________.

  • A. Made of plastic for safety
  • B. Wide enough to support cables without distortion
  • C. Mounted on walls, not ceilings
  • D. Able to support deep bundles of cables

Answer: B


NEW QUESTION # 98
The \_\_\_\_\_\_\_\_\_\_ protects the fiber from harm.

  • A. Aramid fiber strength members
  • B. Jacket
  • C. Primary buffer coating
  • D. All of the above

Answer: D


NEW QUESTION # 99
Physical contact (PC) polish on connectors is designed to reduce \_\_\_\_\_\_\_\_\_\_.

  • A. Loss and reflectance
  • B. Reflectance
  • C. Loss
  • D. Polishing time

Answer: A


NEW QUESTION # 100
Which fiber optic test instrument uses backscattered light for measurements?

  • A. VFL
  • B. OLTS
  • C. OTDR
  • D. Tracer

Answer: C


NEW QUESTION # 101
Information on the safety of chemicals used in fiber optics are __________.

  • A. Available from National Institutes of Health
  • B. Rarely useful
  • C. In MSDS sheets supplied by manufacturers
  • D. Required to be in every installer's tool kit

Answer: C


NEW QUESTION # 102
What is the installed cable plant from work area outlet jack to the patch panel in the telecom closet called?

  • A. Patchcord
  • B. Channel
  • C. Link cable
  • D. Permanent link

Answer: D


NEW QUESTION # 103
The difference between a fiber optic connector and a splice is __________.

  • A. Splices need expensive tools
  • B. Connectors are demountable, while splices are permanent
  • C. Connectors are smaller than splices
  • D. Connectors require adhesives

Answer: B


NEW QUESTION # 104
If you use a Cat 3 UTP jack on newer Cat 5e cable plant, the link performance will meet \_\_\_\_\_\_specs.

  • A. Cat 5
  • B. Cat 6
  • C. Cat 5E
  • D. Cat 3

Answer: D


NEW QUESTION # 105
Premises cables must be rated for \_\_\_\_\_\_\_\_\_\_ to meet codes.

  • A. Weight in cable trays
  • B. Pull strength
  • C. Fire retardance
  • D. Bend radius

Answer: C


NEW QUESTION # 106
When terminating Cat 5e/6, what must be remembered to maintain the performance of the installed cable?

  • A. The jacket of the cable must not be stripped back more than 3 inches
  • B. The punchdown tool must cut off the wires close to the end
  • C. Keep the pairs twisted to within 1/2 inch of the termination
  • D. Do not strip insulation off the wires

Answer: C


NEW QUESTION # 107
Which network connection type has the highest bandwidth?

  • A. Power line
  • B. Wireless
  • C. UTP
  • D. Optical fiber

Answer: D


NEW QUESTION # 108
Prior to cable plant acceptance or system turn-up, standards require that a(n) _______ is used to test the cable plant to ensure it is within the loss budget.

  • A. LSPM or OLTS (Light source and power meter, optical loss test set)
  • B. OTDR
  • C. Power meter
  • D. All of the above

Answer: A


NEW QUESTION # 109
For planning office layout, each user should be allocated \_\_\_\_\_\_\_ floor space.

  • A. 100 sq ft
  • B. shared
  • C. 3 sq m
  • D. Adequate

Answer: A


NEW QUESTION # 110
Why are punchdown blocks used with Cat 3 and Cat 5 cabling?

  • A. Change from T568A to T568B terminations
  • B. Terminate cables from equipment
  • C. Interconnect cables in a telecom closet
  • D. Meet EIA/TIA 568 Standards

Answer: C


NEW QUESTION # 111
The name for the latest generation Cat 6 UTP cable for use with 10 Gigabit networks is \_\_\_\_\_.

  • A. Augmented Cat 6
  • B. Extended Cat 6
  • C. Enhanced Cat 6
  • D. Cat 7

Answer: A


NEW QUESTION # 112
A crimp-on connector like the Cat 5e/Cat 6 connector is also called a \_\_\_\_\_\_\_\_ connector.

  • A. Solderless
  • B. Clipper
  • C. Insulation-displacement
  • D. USOC

Answer: C


NEW QUESTION # 113
IEEE 802.11b has a range of \_\_\_ feet.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C


NEW QUESTION # 114
To maintain rated performance, twists in each pair must be maintained to within \_\_\_\_\_\_\_ of the termination.

  • A. 1/2 inch
  • B. 2.5 cm
  • C. 1 inch
  • D. 25 mm

Answer: A


NEW QUESTION # 115
Category 6A cable is specified and must be tested during certification to \_\_\_ MHz.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B


NEW QUESTION # 116
......