Download Online VALID OSP-002 Exam Dumps File Instantly[May 04, 2023]
OSP-002 Exam Dumps For Certification Exam Preparation
To be eligible for the BICSI OSP-002 Certification Exam, applicants must have a minimum of two years of experience in the ICT industry, specifically in outside plant infrastructure design, installation, and maintenance. In addition, applicants must have completed the BICSI OSP-001 course, which covers the basic principles and practices of outside plant design. Applicants can also meet the eligibility requirements through a combination of education and experience.
NEW QUESTION # 95
Reference cables must match the \_\_\_\_\_\_\_\_ of the cables being tested.
- A. Fiber size and type
- B. Fiber size and connector type
- C. Fiber size and loss specification
- D. Connector type
Answer: B
NEW QUESTION # 96
Singlemode fiber has a __________ light-carrying core than multimode fiber.
- A. Smaller
- B. Larger
- C. Same size
Answer: A
NEW QUESTION # 97
Supports for UTP cables should be __________.
- A. Made of plastic for safety
- B. Wide enough to support cables without distortion
- C. Mounted on walls, not ceilings
- D. Able to support deep bundles of cables
Answer: B
NEW QUESTION # 98
The \_\_\_\_\_\_\_\_\_\_ protects the fiber from harm.
- A. Aramid fiber strength members
- B. Jacket
- C. Primary buffer coating
- D. All of the above
Answer: D
NEW QUESTION # 99
Physical contact (PC) polish on connectors is designed to reduce \_\_\_\_\_\_\_\_\_\_.
- A. Loss and reflectance
- B. Reflectance
- C. Loss
- D. Polishing time
Answer: A
NEW QUESTION # 100
Which fiber optic test instrument uses backscattered light for measurements?
- A. VFL
- B. OLTS
- C. OTDR
- D. Tracer
Answer: C
NEW QUESTION # 101
Information on the safety of chemicals used in fiber optics are __________.
- A. Available from National Institutes of Health
- B. Rarely useful
- C. In MSDS sheets supplied by manufacturers
- D. Required to be in every installer's tool kit
Answer: C
NEW QUESTION # 102
What is the installed cable plant from work area outlet jack to the patch panel in the telecom closet called?
- A. Patchcord
- B. Channel
- C. Link cable
- D. Permanent link
Answer: D
NEW QUESTION # 103
The difference between a fiber optic connector and a splice is __________.
- A. Splices need expensive tools
- B. Connectors are demountable, while splices are permanent
- C. Connectors are smaller than splices
- D. Connectors require adhesives
Answer: B
NEW QUESTION # 104
If you use a Cat 3 UTP jack on newer Cat 5e cable plant, the link performance will meet \_\_\_\_\_\_specs.
- A. Cat 5
- B. Cat 6
- C. Cat 5E
- D. Cat 3
Answer: D
NEW QUESTION # 105
Premises cables must be rated for \_\_\_\_\_\_\_\_\_\_ to meet codes.
- A. Weight in cable trays
- B. Pull strength
- C. Fire retardance
- D. Bend radius
Answer: C
NEW QUESTION # 106
When terminating Cat 5e/6, what must be remembered to maintain the performance of the installed cable?
- A. The jacket of the cable must not be stripped back more than 3 inches
- B. The punchdown tool must cut off the wires close to the end
- C. Keep the pairs twisted to within 1/2 inch of the termination
- D. Do not strip insulation off the wires
Answer: C
NEW QUESTION # 107
Which network connection type has the highest bandwidth?
- A. Power line
- B. Wireless
- C. UTP
- D. Optical fiber
Answer: D
NEW QUESTION # 108
Prior to cable plant acceptance or system turn-up, standards require that a(n) _______ is used to test the cable plant to ensure it is within the loss budget.
- A. LSPM or OLTS (Light source and power meter, optical loss test set)
- B. OTDR
- C. Power meter
- D. All of the above
Answer: A
NEW QUESTION # 109
For planning office layout, each user should be allocated \_\_\_\_\_\_\_ floor space.
- A. 100 sq ft
- B. shared
- C. 3 sq m
- D. Adequate
Answer: A
NEW QUESTION # 110
Why are punchdown blocks used with Cat 3 and Cat 5 cabling?
- A. Change from T568A to T568B terminations
- B. Terminate cables from equipment
- C. Interconnect cables in a telecom closet
- D. Meet EIA/TIA 568 Standards
Answer: C
NEW QUESTION # 111
The name for the latest generation Cat 6 UTP cable for use with 10 Gigabit networks is \_\_\_\_\_.
- A. Augmented Cat 6
- B. Extended Cat 6
- C. Enhanced Cat 6
- D. Cat 7
Answer: A
NEW QUESTION # 112
A crimp-on connector like the Cat 5e/Cat 6 connector is also called a \_\_\_\_\_\_\_\_ connector.
- A. Solderless
- B. Clipper
- C. Insulation-displacement
- D. USOC
Answer: C
NEW QUESTION # 113
IEEE 802.11b has a range of \_\_\_ feet.
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
NEW QUESTION # 114
To maintain rated performance, twists in each pair must be maintained to within \_\_\_\_\_\_\_ of the termination.
- A. 1/2 inch
- B. 2.5 cm
- C. 1 inch
- D. 25 mm
Answer: A
NEW QUESTION # 115
Category 6A cable is specified and must be tested during certification to \_\_\_ MHz.
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
NEW QUESTION # 116
......